Checking the hydraulic oil level
Fig. 204: Parking the machine
A
MAX
MIN
Fig. 205: Oil level indicator on the hydraulic oil reservoir
Adding hydraulic oil
Fig. 206: Hydraulic oil reservoir
OM 803 us – Edition 3.7 * 803b520.fm
1
Park the machine on firm, level and horizontal ground.
2
Position the boom straight ahead at the center of the machine (see figure).
3
Lower the boom and the stabilizer blade to the ground.
4
Stop the engine.
5
Operate the control lever repeatedly to release the pressure in the hydraulic system.
6
Remove the starting key and carry it with you.
7
Sight glass A is located at the rear of the machine.
8
Check the oil level on sight glass A
The oil level must be at the MIN mark if the machine has not reached its operating
temperature yet.
The oil level must be at the MAX mark after the machine reaches its operating
temperature.
Add hydraulic oil if the oil level is below these marks.
9
Slowly open filler cap B with tool C included in the tool kit
10
Add hydraulic oil up to the corresponding mark.
C
11
Check the hydraulic oil level on sight glass A.
12
Add if necessary and check again.
13
Close filler cap B.
Information!
Use a suitable container to collect fluids and lubricants as they flow out and
dispose of them in an environmentally friendly manner.
B
Maintenance
5-17