Maintenance
5.5 Air filter
5-12
NOTICE
The filter elements will be damaged if they are washed or brushed out!
Bear in mind the following to avoid premature engine wear or damage:
• Do not clean the filter elements.
• Replace the air filter element according to the maintenance plan.
• Never reuse damaged filter elements.
• Ensure cleanliness when replacing the filter elements.
NOTICE
Filter elements degrade prematurely when in service in acidic air for longer
periods of time. This risk is present for example in acid production facilities,
steel and aluminum mills, chemical plants and other nonferrous-metal plants.
• Replace air filter element D after 50 operating hours at the latest!
Information!
Ensure that dust valve G shows downward once it is installed!
OM 803 us – Edition 3.7 * * 803b520.fm