Télécharger Imprimer la page

Wacker Neuson 803 Notice D'utilisation page 170

Masquer les pouces Voir aussi pour 803:

Publicité

Les langues disponibles

Les langues disponibles

Maintenance
Battery
+
Fig. 221: Battery
5-30
WARNING
Warning!
Battery acid is highly caustic!
Caustic injury hazard due to battery acid!
Can cause serious injury or death.
• Always wear safety glasses and protective clothing with long sleeves.
If acid is spilt:
• Thoroughly rinse all affected surfaces immediately with plenty of water.
• Thoroughly wash any part of the body touched by the acid immediately with
WARNING
Warning!
Injury hazard due to malfunctioning batteries!
Can cause serious injury or death.
• The battery contains sulfuric acid! This acid must not be allowed to come
• Do not use open flames near open battery cells, avoid sparks close by and
• Do not attempt to jump-start the machine if the battery is frozen or if the
• Always disconnect the negative terminal (–) from the battery before starting
Battery A is located under the floor panel directly in front of the control stand. The battery
A
is "maintenance-free". However check the battery at regular intervals to ensure that the
electrolyte level is between the MIN and MAX marks.
Checking the battery requires it to be removed and must be performed by a Wacker Neu-
-
son service center.
Always follow the specific battery safety instructions!
Information!
Do not disconnect the battery while the engine is running!
plenty of water and seek medical attention at once!
into contact with the skin, the eyes, clothing or the machine.
do not smoke – otherwise the gas that is also produced during normal bat-
tery operation (not only during battery charging) could ignite!
acid level is low. The battery can rupture or explode!
• Replace the battery immediately
repair work on the electrical system!
OM 803 us – Edition 3.7 * * 803b530.fm

Publicité

loading

Produits Connexes pour Wacker Neuson 803

Ce manuel est également adapté pour:

803 dual power