SYSTÈME DE MENUS
DIAGRAMME DU MENU UTILISATEUR
En-tête de Menu. Les valeurs indiquées sont les
Menu Heading
valeurs par défaut d'usine pour le Modèle SW2512.
Élément de Menu- Point de Consigne. Pour les
Menu Item
Setpoint
valeurs par défaut d'autres modèles, voir les
descriptions d'éléments de menu USER et SETUP.
Information
Inverter Mode
Generator Mode
1
Set Inverter
Set Generator
OFF SRCH
ON CHG
OFF AUTO
CHG avail. Only
Gen under/over
speed
in FLT mode.
Generator start
Press red or
error
setpoint button
to move.
Generator sync
Move cursor to
error
Inverter OFF to
Gen max run time
resetOverCurrent
error
Load Amp Start
Ready
Voltage Start
Ready
Exercise Start
Ready
Move cursor to
GEN OFF to reset
Generator error.
If no start in 5
trys then error.
If Gen starts &
runs for 5 min
then stops the
inverter will
not attempt
restart until
gen auto start
conditions are
again satisfied.
If Gen runs for
More than max
Run time then
Error.
Under/Over speed
Will cause a
Sync error in 10
minutes
© 2001 Xantrex Technology, Inc.
Page
5916 - 195th Street N. E.
40
Arlington, WA 98223
MENU HEADINGS
Trace
2
Engineering
3
Press reset now
ON
EQ
for defaults
Revision 4.01
NO
5916 195th St NE
NO
Arlington, WA
98223 USA
NO
Ph
360-435-8826
NO
Fax 360-435-2229
NO
NO
NO
Boutons-poussoirs
du Tableau de
Meters
Error Causes
4
Inverter/charger
Over Current
Amps AC
00
Input Amps AC
Transformer
00
overtemp
Load
Heatsink
Amps AC
00
overtemp
Battery actual
High Battery
volts DC
12.6
voltage
Battery TempComp
Low Battery
volts DC
12.6
voltage
Inverter
Inverter breaker
volts AC
00
tripped
Grid (AC1)
AC source wired
volts AC
00
to output
Generator (AC2)
External error
volts AC
00
(stacked)
Read Frequency
Generator start
Hertz
60
error
Generator sync
AC1 & AC2 volts
valid only when
error
inverter synced
Gen max run time
to that input.
error
Batt volt actual
Gen under/over
is used for
speed
LBCO,HBCO,LBX,
Inverter breaker
tripped
LBCI,sell volts,
and gen starting
Batt volt temp
comp is used,
for float, bulk, eq
& aux relays
Téléphone : 360/435-8826
Fax : 360/435-2229
www.traceengineering.com
Commande
Time of Day
5
00:00:00
6
Set Clock hour
NO
00:00:00
Set Clock minute
NO
00:00:00
Set Clock second
NO
00
NO
NO
Generator Timer
NO
7
Start Quiet
NO
Time
h:m
08:00
End Quiet
NO
Time
h:m
08:00
Gen doesn't run
NO
During quiet
time unless batt
NO
volts is less.
than LBCO volts
NO
for 30 seconds.
To defeat timers
NO
set start = end.
If exercise day
NO
set to 1 then
gen will always
start @ endquiet
End User Menu
8
Onduleur/Chargeur Série SW
Réf. 2031-5
Rév. C : février 2001