LISTE ET DESCRIPTION DES CODES D'ANOMALIE (DTC) DE LA TRANSMISSION ALLISON 4
DTC
C1312
Retarder Request Sensor Failed Low
C1313
Retarder Request Sensor Failed High
P0122
Pedal Position Sensor Low Voltage
P0123
Pedal Position Sensor High Voltage
P0218
Transmission Fluid Over Temperature
P0561
System Voltage Performance
P0562
System Voltage Low
P0563
System Voltage High
P0602
TCM Not Programmed
P0610
TCM Vehicle Options (Trans ID) Error
P0613
TCM Processor
P0614
Torque Control Data Mismatch - ECM/TCM
P0634
TCM Internal Temperature Too High
P063E Auto Configuration Throttle Input Not Present
Auto Configuration Engine Coolant Temp Input Not
P063F
Present
P0658
Actuator Supply Voltage 1 (HSD1) Low
P0659
Actuator Supply Voltage 1 (HSD1) High
TCM Internal Temperature Sensor Circuit Range /
P0667
Perform
P0668
TCM Internal Temperature Sensor Circuit Low
P0669
TCM Internal Temperature Sensor Circuit High
P0701
Transmission Control System Performance
P0702
Transmission Control System Electrical (TransID)
P0703
Brake Switch Circuit Malfunction
P0708
Transmission Range Sensor Circuit High Input
P070C Transmission Fluid Level Sensor Circuit – Low Input
P070D Transmission Fluid Level Sensor Circuit – High Input
Transmission Fluid Temperature Sensor Circuit
P0711
Performance
P0712
Transmission Fluid Temperature Sensor Circuit Low Input
P0713
Transmission Fluid Temperature Sensor Circuit High Input
P0716
Turbine Speed Sensor Circuit Performance
P0717
Turbine Speed Sensor Circuit No Signal
P071A RELS Input Failed On
P071D General Purpose Input Fault
Annexe C – Autres fonctions de la transmission Allison
Description
CHECK
Inhibited Operation
TRANS
Description
Light
May inhibit retarder operation if not
No
using J1939 datalink
May inhibit retarder operation if not
No
using J1939 datalink
Use default throttle values. Freezes
No
shift adapts.
Use default throttle values. Freezes
No
shift adapts.
Use hot mode shift schedule. Holds
No
fourth range. TCC is inhibited.
Freezes shift adapts.
Yes
Lock in Neutral
Yes
Use TID A calibration
No
All solenoids off
Allows operation only in reverse and
Yes
second range.
Yes
SOL OFF (hydraulic default)
Yes
Use default throttle values
No
None
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
Use TID A calibration
No Neutral to Drive shifts for refuse
packer. TCM inhibits retarder
No
operation if a TPS code is also
active.
Yes
Ignore defective strip selector inputs
No
None
No
None
Yes
Use default sump temp
Yes
Use default sump temp
Yes
Use default sump temp
Yes
DNS, Lock in current range
Yes
DNS, Lock in current range
Yes
Inhibit RELS operation
Yes
None
5
È
GÉNÉRATION