Temperature head transmitter
for 2-wire or 3-wire resistor PT-100, fix adjusted measurement range
2-wire electronic 4...20 mA with PNP-switching output or 3-wire electronic 0...10V
BA0207
Electrical data:
Standard measurement ranges:
Output variants _A0 or _AS:
Output variant _B0:
Permitted supply voltage:
Ripple voltage:
Temperature deviation:
Characteristic deviation:
Calibration deviation:
Long term drift:
Influence of supply voltage:
Influence of load:
Delay time output:
Connectable sensor:
PT-100 wire resistance:
EMC specifications:
Switching output: (variant _AS)
Output current:
Rising time:
Adjustment:
Function:
Mechanical data:
Protection:
Material connection head housing:
Connection clamps:
Weight:
Operation temperature:
Storage temperature:
Dewing:
Assembly, electrical installation and inauguration, maintenance:
Assembly, electrical installation, inauguration, operation and maintenance of the device must be carried out by an qualified employee.
The electrical installation of the device must be carried out according to the respective country specific standards.
An incorrect assembly or adjustment could cause applicationally conditioned risks.
The device is maintenance free.
The voltage applied to the clamps may not exceed 50 V at devices of the variants _A0 or _AS and 35 V at devices of the variants _B0 to avoid damage of the
electronic.
All connections are polarity protected.
Use only shielded signal and measurement wires and install these wires separated from power leading wires.
Connect the shield only at one side to earth, ideally at the installation place of the device.
If inductive loads, e.g. relays are connected to the PNP output, an RC protection circuit must be used to avoid high voltage peaks, because they could influence
the properly function of the device
Safety notes:
If a device of the variant Ex KTM_A0 is installed and operated in a hazardous area, the general Ex construction standards (EN60079-14, VDE0165), this safety
notes and the enclosed EC conformity certificate must be observed.
The assembly of an Ex system must be carried out principally by specialist staff.
The devices meets
II 1 G EEx ia IIC T4
II 2 (1) G EEx ia IIC T4 or
U
i
The devices are conceived for measurement of temperatures in hazardous areas.
The measured medium may also be combustible liquids, gases, fogs or steams.
A warning marking points out to the dangers through electrostatic charging of the plastic housing and to the safety measures, that must be applied because of
this dangers in operation mode and especially in the case of maintenance activities.
avoid friction
Approval:
KTM
Ex KTM
0032
__
ACS-CONTROL-SYSTEM GmbH
Lauterbachstraße 57 – 84307 Eggenfelden
Tel: +49 8721/9668-0 – Fax : +49 8721/9668-30
info@acs-controlsystem.de – www.acs-controlsystem.de
RA 0025 - 0100 F Version ATEX Cat. 2 G & Cat. 2(i) G
0870139669 / 100311
Installation and operating instructions
0...+50°C, 0...+100°C, 0...+150°C, 0...+200°C, 0...+250°C, 0...300°C, 0...+400°C, 0...+500°C, 0...+600°C,
-40...+60°C, -50...+100°C, -100...+50°C,
or adjustment by customer specification in the range of –100...+600°C with an measurement span from 20 to 700 Kelvin
4..20mA
temperatur linear from 3,55...20,7 mA, at sensor breakage 21,7 mA, at sensor short circuit 3,55 mA
permitted load
0...10 V
temperature linear from 0 V...10,35 V, at sensor breakage 10,85 V, at sensor short circuit 0 V
permitted load
variants _A0 or _AS
variant _B0
2 V
(condition: within the permitted supply voltage range), f
PP
0,1% / 10 K
0,1%
0,1%
0,05% / year
0,02% / 10 V
0,02% / 100
2 ms
PT-100 in 2- or 3-wire connection
max. 15
each wire
emission
imission
PNP-switching to +V
, V
s
OUT
200 mA, current limited, short circuit protected
< 700 s with R
< 3 k
or I
L
by multi-turn-potentiometer
working current principle (n.o.)
IP00 / IP66 if installed in connection head housing or field housing with corresponding protection
PC
line cross cut max. 1,75 mm
40 g
-40°C...+85°C
-40°C...+100°C
permitted
T
= -20°C...+60°C , pressure from 0,8 bar to 1,1 bar (atmospherically conditions) or
a
= 27,3 V / I
= 140 mA / P
= 0,9 W
i
i
don't clean dry
standard
II 1 G EEx ia IIC T4 for Ex-Zone 0 appropriate ATEX100a (only available for variant Ex KTM _A0)
Measurement temperature range:
A
range
0°C to +50,0°C
B
range
0°C to +100,0°C
C
range
0°C to +150,0°C
E
range
0°C to +200,0°C
F
range
0°C to +250,0°C
G
range
0°C to +300,0°C
H
range
0°C to +400,0°C
Transmitter electronic:
A0
4...20 mA
2-wire-electronic
AS
4...20 mA
2-wire-electronic with PNP-switching output
B0
0...10 V
3-wire-electronic
__
__
see scheme
2500
at 10 V, equals 4 mA, current limited
+8,5 V to 40 V DC (max. 50 V DC), polarity protected
+14 V to 35 V DC, polarity protected
max
of nominal measurement range
of nominal measurement range
of nominal measurement range
of nominal measurement range
of nominal measurement range
of nominal measurement range
appropriate EN 50081-1
appropriate EN 50082-2
+Vs – 1,5 V
> 4,5 mA
L
2
, screws everlasting
II 2 G EEx ib IIC T4
don't assemble in pneumatic conveying stream
J
range
0°C to +500,0°C
L
range
0°C to +600,0°C
Q
range
-40°C to +60,0°C
O
range
-50°C to +100,0°C
N
range
-100°C to +50,0°C
Y
adjustment by customer specification (note range!!!)
Documentation sur l'équipement de mesure et de sécurité
Page 2 of 2
= 1 kHz
Max. load resistance in dependence of
the supply voltage
R
/Ohm
L
1450
700
8,5
24
T
= -40°C...+85°C
a
KTM
40
U
/V
VS
Seite 2 von 2
page 29