Technical Data; Operating Conditions; Ambient Temperature And Installation Site Altitude; Shaft Seal - Biral HP 95-100-1/1 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

30
English
|
11.

Technical data

11.1

Operating conditions

11.1.1

Ambient temperature and installation site altitude

If the ambient temperature exceeds +40°C or if the motor is more than 1,000 metres above sea
level, the motor power (P2) must be reduced due to the lower air density and the resulting dimin-
ished cooling effect. In such cases it may be necessary to choose a larger motor.
Fig. 24 Motor power P2 according to ambient temperature t and altitude of installation site.
As a fundamental rule, the max. ambient temperature of +40°C should not be exceeded.
11.1.2
Maximum permissible operating pressure and fluid temperature for shaft seal
The operating range of a shaft seal is dependent on the operating pressure, the fluid temperature
and the type of shaft seal. The selection chart shows which shaft seal is suitable for which fluid
temperature and operating pressure. See Fig. 25. The chart applies to clean water.
Shaft seals for shaft end diameter 22: HP/HPC with motors up to 55kW
Fig. 25 Maximum permissible operating pressure and fluid temperature for pumps with shaft seal diameter 22
and motor up to 55kW
Item
Motor power [kW]
1
0.37–0.55
2
0.75–22
3
30.0–75

Publicité