Installation; Assembly; Important; Installation Instructions - Biral HP 95-100-1/1 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

16
English
|
6.

Installation

Warning
Fix the pump on a firm and level surface according to the specifications in the instal-
lation and operating instructions.
6.1

Assembly

Important

Before the pump can be used to pump drinking water, it must be thoroughly
flushed through with clean water. Do not use the pump to pump drinking water if
the internal components have come into contact with particles or substances that
are not suitable for use in water intended for consumption.
6.1.1

Installation instructions

The pump must be set up on a firm, flat and horizontal surface and fixed on the base plate with
bolts. So that the pump is not damaged, the following instructions should be followed when
installing it:
1.
2.
3.
The arrows on the pump pedestal indicate the
direction of flow of the fluid.
The following dimensions in Appendix A indi-
cate:
Installed length of the pump
Size of the pedestal
Pipe connection options
Arrangement of bolt holes in the pedestal
and their diameters.
The pump can be installed either vertically or
horizontally. However, the motor must never
face downwards! If the pump is to be operated
in a horizontal position, the version with pedes-
tal motor must be ordered.
A sufficient supply of air for cooling the motor
must always be ensured.