4.4
Floating ring seal
As standard, the type HP pumps are fitted with a cartridge-type floating ring seal, which is suitable
for most applications. It is essential to take the following parameters into account when choosing
the floating ring seal:
•
Type of fluid being pumped
•
Fluid temperature
•
Maximum operating pressure
If water additives are used, the choice of floating ring seal must be reviewed. Specifically for
anti-freeze additives in proportions of 30% or more (e.g. glycol or similar) a special design may
need to be used. Please contact Biral for further guidance.
5.
Delivery
5.1
Moving and unpacking the pump
The pump and motor are delivered on a euro/non-returnable pallet in the packing provided. When
moving the pump, attention must be paid to the handling equipment (forklift, crane) and stability.
Consignment dimensions and weights are detailed in the technical data. The general accident
prevention regulations should be observed!
Warning
Make sure that the product is kept stable and securely held at all times while being
moved. Always wear the appropriate personal protective equipment when perform-
ing the task.
For the sake of the environment...
We are sure you will understand that a certain amount of packing for transportation
is unavoidable. Please help to protect our environment by disposing of used materi-
als in accordance with the relevant regulations or re-using them.
5.2
Checking the pump
Before installing the pump, please make sure of the following:
1.
Check that the product matches the specifications of the order.
2.
Satisfy yourself that the product shows no visible signs of damage.
Should any parts be missing or damaged, please contact Biral without delay.