230 V electrical connection and
IR receiver connection
The electrical connection must always be made by
an expert (in accordance with VDE 0100, part 721 or
IEC 60364-7-721 in Germany)! The instructions shown here do
not constitute a request to non-experts to make the electrical
connection, but serve as additional information for an expert
who is employed to do the work!
Fig. 20
Unscrew 2 screws (14) and open the electronic housing lid.
Fig. 21
Insert mains cable plug (15) into socket. The plug is automati-
cally provided with strain relief by engaging in a retaining lug.
The retaining lug must be lifted with a screwdriver in order to
remove the plug from the socket.
Insert IR receiver plug into socket (16).
The connection (17) is needed if the Saphir vario air con-
ditioning system is being operated via a Truma TG 1000
sinus power inverter (COM connection / communication a
or b).
Close electronic housing lid again and screw the screws (14)
back in.
The cables must be long enough for the device to be pulled
out of the false floor with the cables attached. All cables must
be secured with clamps!
An insulating device for providing all-pole insulation from
the mains with contact clearance of at least 3.5 mm must be
provided at the vehicle side for carrying out maintenance and
repair work.
26
17
16
15
Function test /
remote control cradle
Position remote control cradle as close as possible to the re-
ceiver (9) so that the air conditioning system can be operated
without removing the remote control from the cradle.
All device functions must subsequently be tested as described
in the operating instructions.
The operating instructions must be handed over to the vehicle
owner.