Start-up

Before switching on, be sure to check that the camp site
power supply fusing is sufficient (230 V / 600 W / 1.7 A,
1500 W / 3.0 A, 2000 W / 4.4 A).
In order to prevent the power cable of the recreational
vehicle from overheating (minimum cross-section 3 x
2.5 mm²) the cable drum must be fully unwound.
The remote control must always be pointed at the infra-red re-
ceiver in order to perform the individual switching commands.
Before switching on for the first time, the remote control must
be tuned to the IR receiver.
– Insert batteries (pay attention to polarity)
– Setup symbol flashes
(if symbol does not flash, perform Reset)
– Point remote control at IR receiver
– Press Setup button and hold down
– When the red LED on the IR receiver starts to flash, release
Setup button.
The remote control is tuned to the IR receiver, the Setup sym-
bol goes off and the air conditioning system starts in circu-
lated air mode, at low fan level and with no timer set.

Switching on

Switch on the air conditioning system using the "On/Off
switch" of the remote control. The previous settings are
taken over.
The circulated air fan runs after switching on. The com-
pressor switches itself on after no more than 3 minutes,
and the green LED (cooling) flashes.

Temperature

If necessary, use the "Temperature selection buttons" to
set the required room temperature with "+" and "–".

Mode

Select the required operating mode by pressing the "MODE"
button one or more times.
– Cooling
COOL LOW (600 W)
COOL (1500 W)
COOL HIGH (2000 W)
– Circulated air
When the room temperature that was selected using the re-
mote control is reached in cooling mode, the compressor
switches off and the green LED in the IR receiver goes off. The
circulated air fan continues to run in order to provide ventila-
tion. If the room temperature setting is exceeded, the device
automatically reverts to cooling mode.
In Circulated air mode the interior air is recirculated and
cleaned by the filter. No LED's illuminate in the IR receiver.

Fan

Select the required fan level by pressing the "Fan level" but-
ton one or more times.
Fan level
– low
– high
18

Sleep function

In "Sleep function" (lowest cooling level only) the fan oper-
ates at slow speed and therefore extremely quietly.

Switching off

To switch off, press the "On/Off switch" on the remote con-
trol. The remote control and the device are switched off.
If the air conditioning system is switched on again, the
green LED flashes. The air circulation fan runs, and the
compressor activates itself after no more than 3 minutes.

Time

Press "Time selection button" (time flashes) and set cur-
rent time using the "Time setting" buttons.
The time always appears on the display.
The time needs to be set again after a battery change, chang-
ing the clock forward or back, or after the remote control and
the IR receiver have been re-tuned.

Timer OFF

With the integrated timer the deactivation time of the air
conditioning system can be set in advance for a minimum
of 15 minutes to a maximum of 24 hours, starting from the
current time.
The device must be switched on using the remote control in
order to program it.
Set required operating mode and room temperature.
Then select TIMER OFF. Set the required deactivation time us-
ing the "Time setting" buttons (15 minutes to 24 hours) and
confirm with TIMER OFF.
Pressing the Timer OFF button again deactivates the timer
function.
The air conditioning system must remain switched on
for the programming to remain active. The remote control
itself can be deactivated by covering the infrared transmitter
on the front of the remote control. This prevents unintentional
air conditioning system deactivation and accidental repro-
gramming of the deactivation time.

Reset

Resets the settings of the remote control to the factory set-
tings when pressed using a ballpoint pen, for example. Setup
symbol flashes. Remote control settings set to "Circulated
air", fan level low, no timer set.

Resend

The previous settings are resent.

Setup

Tune the remote control to the air conditioning system that is
going to be operated. Settings set to "Circulated air", fan level
low, no timer set.