Setup
Tune the remote control to the air conditioning system that is
going to be operated.
IR receiver and manual on / off
There is an additional pushbutton on the IR receiver (m), with
which the unit can also be switched on and off without the
remote control (e.g. with a ballpoint pen).
If the unit is switched on using this pushbutton, the system is
automatically reset to the factory settings (automatic mode,
22 °C).
IR receiver / function display
m
LED 1
Figure 2
LED 1 blue – illuminated – (cooling mode)
LED 1 blue – flashing – (cooling mode compressor start-up)
LED 2 red – flashing – (data transfer in progress)
LED 2 red – illuminated – (fault)
LED 1 and LED 2 illuminated
Red LED illuminated
The appliance is indicating a fault. Switch the appliance off,
wait for a short time and switch on again. If red light stays on,
contact Truma Service.
Air distribution
Right / left
There are two individually adjustable air outlets at the front
and rear.
Front / rear
The air flow can be metered between the front and rear areas
of the vehicle.
Ceiling / floor
The air flow can be directed from the ceiling to the floor.
Front / rear
Right / left
Ceiling /
floor
Right / left
IR receiver /
function display
Figure 3
LED 2
(230 V interrupted ,
compressor switches off)
Right / left
Ceiling /
floor
Right / left
IR remote control battery change
Only use micro-batteries that will not leak, type LR 3, AM4,
AAA, MN 2400 (1.5 V).
The battery compartment is on the back of the remote control.
When inserting new batteries, make sure
the positive / negative terminals are con-
nected correctly.
Remove the batteries if the remote con-
trol is not being used for a long period of
time.
Figure 4
No warranty is given for damage caused by leaking
batteries.
Disposal
Neither the remote control nor the batteries may be
disposed of with domestic refuse, instead they must be
sent for recycling separately via a collection point. By
doing this you are contributing towards reuse and recycling.
The tuning between the remote control and the air con-
ditioning system is retained if the batteries are removed.
Maintenance
Maintenance, repairs and cleaning must not be done by
children.
Carry out filter changes depending on the amount of use, but
at least every 12 months.
On the air distributor small, remove the panels and clean un-
der clear / lukewarm water.
Never operate the air conditioning system without a filter /
panels. This can lead to loss of power. Keep the air inlets /
outlets and the condensation traps on the roof free of obstruc-
tions such as leaves at all times. The air conditioning system
should only be cleaned with a soft, damp cloth.
Disposal
The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-life Vehicle Regulation) must be observed.
The relevant regulations must be observed in other countries.
Empty, used batteries can leak
and damage the remote control!
EN
15