Start-Up; Switching On; Mode; Fan - Truma Aventa compact Mode D'emploi

Masquer les pouces Voir aussi pour Aventa compact:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20

Start-up

Before switching on, be sure to check that the camp site has
adequate power supply fusing (230 V).
In order to prevent the power cable of the recreation-
al vehicle from overheating (minimum cross-section
3 x 2.5 mm²) the cable drum must be fully unwound.
The remote control must always be pointed at the infrared re-
ceiver in order to perform the individual switching commands.
Before switching on for the first time, the remote control must
be tuned to the IR receiver.
– Insert batteries (pay attention to polarity)
– Setup symbol flashes
(if symbol does not flash, perform Reset)
– Point remote control at IR receiver
– Press Setup button and hold down
– When the red LED on the IR receiver starts to flash, release
the Setup button.
The remote control is tuned to the IR receiver, the Setup sym-
bol goes off and the air conditioning system starts in circulat-
ed air mode, at low fan level and with no timer set.

Switching on

Switch on the air conditioning system using the "On / Off
switch" of the remote control. The last selected settings are
taken over.
The circulated air fan runs after switching on. The com-
pressor switches itself on after no more than 3 minutes,
and the blue LED flashes.
Temperature
If necessary, use the "Temperature selection buttons" to
set the required room temperature with "+" and "–".

Mode

Select the required operating mode by pressing the "MODE"
button one or more times.
– Cooling
– Automatic
– Circulated air
When the room temperature that was selected using the re-
mote control is reached in cooling mode, the compressor
switches off and the blue LED in the IR receiver goes off. The
circulated air fan continues to run in order to provide ventila-
tion. If the room temperature setting is exceeded, the appli-
ance automatically reverts to cooling mode.
. If the air humidity in the vehicle is extremely high at
the beginning of the cooling procedure, moisture can
build up on the underside of the air distributor. The doors and
windows should therefore be kept closed and the highest fan
level selected.
In automatic mode, the fan level is selected automatically
depending on the room temperature.
In circulated air mode, the interior air is recirculated and
cleaned by the filters / panels No LED's illuminate in the
IR receiver.

Fan

Select the required fan level by pressing the "Fan level" but-
ton one or more times.
14
EN
Fan level (not functional in automatic mode):
– low
– medium
– high

Sleep function

In "Sleep function" the internal and external fans operate at
slow speed and are therefore extremely quiet.

Switching off

To switch off, press the "On / Off switch" on the remote
control. The remote control and the appliance are switched off.
* The light can still be switched on and off using the
"Ambient lighting" button.
* No function in the case of air distributor small
The blue LED flashes when the air conditioning system
is switched back on. The circulated air fan runs, and the
compressor switches on after no more than 3 minutes.

Time

Press the "Time selection button" and set the current time
using the "Time setting" buttons.
The time is always shown on the display (exception with
ON / OFF timer).
The time must be reset after changing the batteries or after a
daylight saving time change.

Timer ON / OFF

The On / Off time of the air conditioning system can be set
in advance for a minimum of 15 minutes to a maximum of
24 hours, starting from the current time, using the integrated
timer.
The appliance must be switched on using the remote control
in order to program it.
Set required operating mode and room temperature.
Then select TIMER ON or TIMER OFF using the "TIMER
selection buttons". Set the required On / Off time using
the "Time setting" buttons (15 minutes to 24 hours) and
confirm with TIMER ON or TIMER OFF.
Pressing the relevant timer button again deactivates the timer
function.

* Ambient lighting

Irrespective of whether the air conditioning system is oper-
ating, the lighting in the air distributor can be switched on or
off by pressing the "Ambient lighting" button. The lighting
is dimmed by pressing and holding down the "Ambient
lighting" button. The previous setting is activated when it is
switched on again.
* No function in the case of air distributor small

Reset

Resets the settings of the remote control to the factory set-
tings when pressed using a ballpoint pen, for example. Setup
symbol flashes.

Resend

The previous settings are resent.

Publicité