Start-up

Before switching on, be sure to check that the camp site
power supply fusing is sufficient (230 V).
In order to prevent the power cable of the recreational
vehicle from overheating (minimum cross-section
3 x 2.5 mm²) the cable drum must be fully unwound.
The remote control must always be pointed at the infra-red re-
ceiver in order to perform the individual switching commands.
Before switching on for the first time, the remote control must
be tuned to the IR receiver.
– Insert batteries (pay attention to polarity)
– Setup symbol flashes
(if symbol does not flash, perform Reset)
– Point remote control at IR receiver
– Press Setup button and hold down
– When the red LED on the IR receiver starts to flash, release
Setup button.
The remote control is tuned to the IR receiver, the Setup sym-
bol goes off and the air conditioning system starts in circu-
lated air mode, at low fan level and with no timer set.

Switching on

Switch on the air conditioning system using the "On/Off
switch" of the remote control. The previous settings are
taken over.
The circulated air fan runs after switching on. The com-
pressor switches itself on after no more than 3 minutes,
and the blue LED flashes.
Temperature
If necessary, use the "Temperature selection buttons" to
set the required room temperature with "+" and "–".

Mode

Select the required operating mode by pressing the "MODE"
button one or more times.
– Cooling
– Automatic
– Circulated air
When the room temperature that was selected using the re-
mote control is reached in cooling mode, the compressor
switches off and the blue LED in the IR receiver goes off. The
circulated air fan continues to run in order to provide ventila-
tion. If the room temperature setting is exceeded, the device
automatically reverts to cooling mode.
The air is dehumidified during cooling. If the air humidity
in the vehicle is extremely high at the beginning of the
cooling procedure, moisture can build up on the underside of
the air distributor. The doors and windows should therefore be
kept closed and the highest fan level selected.
In Automatic mode the fan level is selected automatically
depending on the room temperature.
In Circulated air mode the interior air is recirculated and
cleaned by the filter. No LED's illuminate in the IR receiver.

Fan

Select the required fan level by pressing the "Fan level" but-
ton one or more times.
Fan level (not functional in automatic mode):
– low
– medium
– high

Sleep function

In "Sleep function" the internal and external fans operate at
slow speed and are therefore extremely quiet.

Switching off

To switch off, press the "On/Off switch" on the remote con-
trol. The remote control and the device are switched off. The
light can still be switched on and off using the "Ambient
lighting" button.
If the air conditioning system is switched on again, the
blue LED flashes. The air circulation fan runs, and the
compressor activates itself after no more than 3 minutes.

Time

Press "Time selection button" and set current time using
the "Time setting" buttons.
The time is always shown on the display (exception with ON /
OFF timer).
The time must be reset after changing the batteries or after a
daylight saving time change.

Timer ON / OFF

With the integrated timer the On/Off time of the air condition-
ing system can be set in advance for a minimum of 15 min-
utes to a maximum of 24 hours, starting from the current
time.
The device must be switched on using the remote control in
order to program it.
Set required operating mode and room temperature.
Then select TIMER ON or TIMER OFF using the "TIMER
selection buttons". Set the required On/Off time using the
"Time setting" buttons (15 minutes to 24 hours) and con-
firm with TIMER ON and TIMER OFF.
Pressing the relevant timer button again deactivates the timer
function.

Ambient lighting

Irrespective of whether the air conditioning system is oper-
ating, the lighting in the air distributor can be switched on
and off using the "Ambient lighting" button. The lighting
is dimmed by pressing and holding down the "Ambient
lighting" button. The previous setting is activated when it is
switched on again.

Reset

Resets the settings of the remote control to the factory set-
tings when pressed using a ballpoint pen, for example. Setup
symbol flashes.

Resend

The previous settings are resent.

Setup

Tune the remote control to the air conditioning system that is
going to be operated. Settings set to "Circulated air", fan level
low, no timer set.
17