Start-up

Before switching on, be sure to check that the camp site has
adequate power supply fusing (230 V).
In order to prevent the power cable of the recreational
vehicle from overheating (minimum cross-section
3 x 2.5 mm²) the cable drum must be fully unwound.
The remote control must always be pointed at the infrared re-
ceiver in order to perform the individual switching commands.
Before switching on for the first time, the remote control must
be tuned to the IR receiver.
– Insert batteries (pay attention to polarity)
– Setup symbol flashes
(if symbol does not flash, perform Reset)
– Point remote control at IR receiver
– Press Setup button and hold down
– When the red LED on the IR receiver starts to flash, release
the Setup button
The remote control is tuned to the IR receiver, the Setup sym-
bol goes off and the air conditioning system starts in circu-
lated air mode, at low fan level and with no timer set.

Switching on

Switch on the air conditioning system using the
"On / Off switch" of the remote control. The last
selected settings are taken over.
The circulated air fan runs after switching on. The com-
pressor switches itself on after no more than 3 minutes,
and the blue (cooling) / yellow (heating) LED flashes.

Temperature

If necessary, use the "Temperature selection buttons" to
set the required room temperature with "+" and "–".

Mode

Select the required operating mode by pressing the "MODE"
button one or more times.
– Cooling
– Heating
– Automatic (cooling or heating mode, depending on the
room temperature setting)
– Circulated air
When the room temperature that was selected using the re-
mote control is reached in cooling mode, the compressor
switches off and the blue LED in the IR receiver goes off. The
circulated air fan continues to run in order to provide ventil-
ation. If the room temperature setting is exceeded, the device
automatically reverts to cooling mode.
The air is dehumidified during cooling. If the air humidity
in the vehicle is extremely high at the beginning of the
cooling procedure, moisture can build up on the underside of
the air distributor. The doors and windows should therefore be
kept closed and the highest fan level selected.
When the room temperature that was selected using the
remote control is reached in heating mode, the compressor
switches off and the yellow LED in the IR receiver goes off.
The circulated air fan continues to run in order to provide ven-
tilation. If the temperature drops below the room temperature
setting, the device automatically switches to heating mode.
Heating at an outside temperature of less than 4 °C is
not possible because heating performance falls con-
siderably. Between 4 °C and 7 °C the device switches briefly
to defrosting processes. At above 7 °C there are no restric-
tions on heating mode.
In automatic mode, cooling / heating mode and the fan
level are selected automatically depending on the room
temperature.
In circulated air mode, the interior air is recirculated and
cleaned by the filters. No LED's illuminate in the IR receiver.

Fan

Select the required fan level by pressing the "Fan level" but-
ton one or more times.
Fan level (not functional in automatic mode):
– low
– medium (not in heating mode)
– high

Sleep function

In "sleep function" (cooling mode only), the internal and ex-
ternal fans operate at slow speed and are therefore extremely
quiet.

Switching off

To switch off, press the "On / Off switch" on the remote
control. The remote control and the device are switched off.
The light can still be switched on and off using the
"Ambient lighting" button.
If the air conditioning system is switched on again, the
blue / yellow LED flashes. The circulated air fan runs, and
the compressor switches on after no more than 3 minutes.

Time

Press the "Time selection button" and set the current time
using the "Time setting" buttons.
The time is always shown on the display (exception with
ON / OFF timer).
The time must be reset after changing the batteries or after a
daylight saving time change.

Timer ON / OFF

The On / Off time of the air conditioning system can be set
in advance for a minimum of 15 minutes to a maximum of
24 hours, starting from the current time, using the integrated
timer.
The device must be switched on using the remote control in
order to program it.
Set required operating mode and room temperature.
Then select TIMER ON or TIMER OFF using the
"TIMER selection buttons". Set the required On / Off time
using the "Time setting" buttons (15 minutes to 24 hours)
and confirm with TIMER ON or TIMER OFF.
Pressing the relevant timer button again deactivates the timer
function.

Ambient lighting

Irrespective of whether the air conditioning system is oper-
ating, the lighting in the air distributor can be switched on or
off by pressing the "Ambient lighting" button. The lighting is
dimmed by pressing and holding down the "Ambient lighting"
button. The previous setting is activated when it is switched on
again.
17