1. Examine the dust extraction hoses for damages.
2. Make sure that the filters in the dust collector are
clean and not damaged.
3. Attach the two 5 m/16.5 ft. dust extraction hoses to
the dust collector with hose clamps and industrial
tape.
4. Install the Y-connector, the 2 m/6.5 ft. dust extraction
hose, the 2-way valve and the 15 m/50 ft. dust
extraction hose. Refer to
overview on page 15 .
5. Put the 15 m/50 ft. dust extraction hose through the
support pipe.
6. Attach the 15 m/50 ft. dust extraction hose to the
product with hose clamps and industrial tape.
To connect the product to a power
source
1. Connect the power plug of the product to a grounded
mains outlet or other power source.
2. Make sure that the mains voltage agrees with the
type plate on the product.
To adjust the distance between the
steel wire ropes and the surface
The correct distance between the steel wire ropes
and the surface is 349–355 mm/13.5–14 in. (A). The
connection points on the rigging system must align with
the entry points for the steel wire ropes on the product.
1. Install an applicable rigging system. Refer to the
related operator's manual.
2. Attach the steel wire ropes to the suspensions for
steel wire rope on the rigging system.
16
Dust collector connection,
A
3. Adjust the suspensions for the steel wire rope until
the distance between the steel wire rope and the
surface is correct. Refer to the operator's manual for
the rigging system for instructions.
4. Put the steel wire ropes through the winches. Refer
To put the steel wire ropes through the winches
to
on page 16 .
5. Move the product up a small distance. Refer to
do a test lift of the product on page 18 .
6. Measure the distance between the steel wire rope
and the surface and make sure that it is correct.
Adjust the distance if it is necessary.
To put the steel wire ropes through the
winches
WARNING:
wire ropes are clean and not damaged.
To examine the steel wire ropes on
Refer to
page 27 .
WARNING:
move and transport the steel wire ropes.
WARNING:
product when you install the steel wire
ropes.
WARNING:
are necessary for this procedure. 2 persons
supply the steel wire ropes to the winches
and 1 person looks at the procedure and
pushes the emergency stop if there is an
emergency.
1. Put the steel wire ropes between the rollers on each
side of the product.
To
Make sure that the steel
Use lifting equipment to
Do not stay below the
A minimum of 3 persons
2149 - 001 - 02.11.2023