Pulse Waveforms
A shown below, a pulse waveform consists of a period, a pulse width, a rising
edge, and a falling edge.
50%
Pulse Period
– Pulse period: 200 ns to 1000 s. The default is 1 ms.
– The specified period must be greater than the sum of the pulse width and the
– Front-Panel Operation: After selecting the pulse function, press the Freq
– Remote Interface Operation:
Keysight 33210A User's Guide
90%
Pulse Width
10%
Rise Time
edge time as shown below. The function generator will adjust the pulse width
and edge time as needed to accommodate the specified period.
Period > Pulse Width + (1.6 × Edge Time)
softkey again to toggle to the Period softkey. Then use the knob or numeric
keypad to enter the desired pulse period.
PULSe:PERiod {<seconds>|MINimum|MAXimum}
90%
Fall Time
Period
Features and Functions
50%
10%
3