Télécharger Imprimer la page

Keysight 33210A Guide D'utilisation page 126

Générateur de signaux arbitraires/fonctions 10 mhz

Publicité

3
Features and Functions
Software (Bus) Triggering
The bus trigger mode is available only from the remote interface. This mode is
similar to the manual trigger mode from the front panel, but you trigger the
function generator by sending a bus trigger command. The function generator
initiates one sweep or outputs one burst each time a bus trigger command is
received.
– To select the bus trigger source, send the following command.
– To trigger the function generator from the remote interface (GPIB, USB, or
126
TRIGger:SOURce BUS
LAN) when the Bus source selected, send the TRIG or *TRG (trigger)
command. The front-panel
is waiting for a bus trigger.
key is illuminated when the function generator