Push the exit key
IMPORTANT:
repeat the operation if necessary if synchronisation was not successful.
The machine can recognise a certain number of malfunction conditions and signals them
by displaying the relevant messages.
A 3
wheel not suitable for performing the sensitivity calibration, use a wheel of
average dimensions (typically 5.5"X14") or larger, but NOT exceeding a weight
of 40kg.
A 5
Incorrect dimension settings for an ALU programme. Correct the set dimen-
sions.
A 7
The machine is temporarily unable to select the requested programme.
Perform a wheel spin, then repeat the request.
A 20
Ultrasonic sensor calibration template in an incorrect position during calibra-
tion. Bring it to the position indicated and repeat the calibration.
A 26
Programme available only after selecting one of the following programmes:
ALU 1P / ALU 2P / Motorcycle Dynamic / Motorcycle ALU or if selected in the
Motorcycle Programme but with the wheel NOT in the centred position.
A 31
Optimisation procedure (OPT) already launched by another user.
A 52
Initiated the procedure for assembly of the hub of auto wheel locking system.
After 60 seconds, the procedure ends automatically.
A Stp
Wheel stop during the spin phase.
Wheel movement is not integral with swinging unit movement: Check correct
wheel tightening.
A Cr
Spin performed with the guard raised.
Lower the guard to perform the wheel spin.
E 1
Absence of sensitivity calibration.
Perform the sensitivity calibration procedure.
E 2
Error condition during sensitivity calibration.
Repeat sensitivity calibration paying attention to the first spin, which must
be performed with the wheel as in the successive spins.
Take particular care NOT to knock the machine during calibration.
E 3 I/E 2/3 Error condition at the end of sensitivity calibration. Repeat the calibration, if
the message persists perform the following checks:
• Correct sensitivity calibration procedure;
• Correct fastening and position of the calibration weight;
• Mechanical and geometric condition of the calibration weight;
134
to exit the program without performing the synchronisation.
ERROR MESSAGES
– A – Notice Messages
– E – Error messages
Operator's Manual EM 9380 XLine - EM 9380C XLine