5.
perform a second spin.
6.
At the end of the spin, change the position of the calibration weight on the shaft
assembly bell as indicated in figure 27;
7.
Perform a third spin. This last calibration phase includes the execution of three
consecutive spins in automatic mode.
If the calibration has been successful, a permission acoustic signal goes off at the end of
the spin; otherwise, the E 2 message is temporarily displayed.
Notes:
- Once the procedure is finished, remove the calibration weight;
- Press the
- This calibration is valid for any kind of wheel.
Calibration of the ultrasonic width sensor (if installed)
Used to calibrate the ultrasonic sensor located on the wheel guard pipe (width). It must
be performed when the machine requests it by displaying the E4 message, or when the
measured and the actual rim widths differ.
- select the ultrasonic width sensor calibration icon
programmes;
- fix the calibration template in correspondence of the threaded hole located in the shaft
assembly bell using the M8 screw (A, Fig.28) supplied with the ultrasonic sensor;
- use the locking device with a wheel spacer (machine version with automatic locking
system) or a cone and the wheel fixing nut to bring the template in contact with the
shaft assembly bell (fig.28);
Operator's Manual EM 9380 XLine - EM 9380C XLine
button to interrupt the calibration procedure at any time.
27
located in the configuration
UK
131