the sensor support. To access the sensor
support, remove the plastic casing by
unscrewing the four fixing screws (Fig.6c).
- check and if necessary act on the ultrasonic
sensor support until obtaining the required
distance between the calibration template
and the support itself (Fig.6d), proceeding
as follows:
1. Fix the calibration jig of the ultrasonic
sensor in the kit to the shaft of the oscilla-
ting unit using the centering accessories;
2. Lower the wheel guard;
CAUTION
Lowering the wheel protection enables the launch of the oscillating unit with the tem-
plate locked !!!
3. Align the calibration gauge of the ultrasonic sensor with the ultrasonic sensor holder
and check its distance, ie:
a. 270mm (tolerance +/- 5mm)
IMPORTANT: after installing the ultrasonic sensor, calibrate the sensor as described
in the paragraph "Calibrating ultrasonic width measuring sensor".
After assembling the machine, posi-
tion it in the selected place and make
sure that the spaces surrounding it
are at least equal to the ones indi-
cated in fig.7.
Operator's Manual EM 9380 XLine - EM 9380C XLine
6d
UK
7
85