- Select the lighting LED activation/deactivation icon
- Three icons will appear on the display, representing the possible light modes:
LED1. In this configuration, the light turns on when:
- an ALUP programme is set and the internal sensor is extracted. When the sensor returns
to the rest position, the light turns off;
- at the end of a spin cycle if residual unbalances are present for 30 seconds;
- in CP (centred position) for an additional 30 seconds.
LED2. In this configuration, the light turns on in the conditions indicated for the LED1
programme and, in addition, also in the following conditions:
- during the entire measuring cycle and with all balancing programmes;
- during the Hidden Weight programme when selecting the two planes behind the spokes.
LED OFF: deactivated
- Using the Enter button
if it is in the following configuration:
- press
to confirm the selection made and exit the function.
It is possible to activate or deactivate the laser when present on the machine.
After the list of the setting programmes is displayed:
- Select the LASER activation/deactivation icon
- Two icons will appear on the display that represent the possible LASER modes, as
shown below:
LASER OFF.
LASER ON. In this configuration, the laser turns on in the following cases:
- for the manual application of all adhesive weights.
IMPORTANT:
If the operator selected an ALU1P or ALE2P (precise) balancing programme and there is a
weight holder, the laser will not be activated as the weight is applied using the holder itself.
- in the Hidden Weight programme, the selection of the two new positions behind the
spokes is done in the 6 o'clock position using the laser line.
- Using the Enter button
if it is in the following configuration:
Operator's Manual EM 9380 XLine - EM 9380C XLine
, select the desired mode. The selected icon is enabled
LASER activation/deactivation
, select the desired mode. The selected icon is enabled
UK
129