8. Automatic door commands (only ABP-A)
Order
RO=LLLRRRUUU
OA
WS 0
WS 1
CR
WS 2
CL
OU
CU
DOORR
DOORL
127
Function
Settings of the open position for each door
LLL: open position of the left door. Set value between 20 and
100 (%).
RRR: open position of the right door. Set value between 20
and 100 (%).
UUU: open position of the upper door. Set value between 20
and 100 (%).
Open the upper, right and left door (all 3)
Close the upper, right and left door (all 3)
Open the right door
Close the right door
Open the left door
Close the left door
Open the upper door
Close the upper door
Button to open and to close the door (right)
Button to open and to close the door (left)