INTRODUCTION

Carefully read this manual before proceeding
with installation operations, use, maintenance
or other intervention operations on the device.
Always keep this manual at hand.
Important: To avoid damages to persons or
things, read with particular attention all the
paragraphs "Safety Requirements" present in
the manual.
According to the degree of severity the safety
requirements are classified with the following
indications:
WARNING: (Always referred to damage
to persons)
CAUTION: (Referring to possible
damages to things)
The aim of this manual is to make the operators
aware of the safety regulations, installation
1.1

Intended Use

PIEZOSURGERY® white is a piezoelectric
ultrasonic device intended for oral bone
surgery in the following applications:
• osteotomy and osteoplasty techniques;
• implantology;
• periodontal surgery;
• orthodontic surgery;
• endodontic surgery;
• maxillofacial surgery
PIEZOSURGERY® white,
can operate as a piezoelectric scaler in the
following dental applications:
• scaling: all the procedures for the
removal of bacterial plaque deposits
and supra-gingival, sub-gingival, and
interdental calculi, and for the removal
of stains;
• periodontology: periodontal treatment
for the scaling and root-planing/
debridement without damage to the
periodontium, including cleaning and
irrigation of the periodontal pocket;
1 http://mectron.it/en/technical-support/users-manuals/
procedures, instructions for proper use and
maintenance of the device and its accessories.
Use of this manual for aims other than those
strictly linked to the installation, use and
maintenance of the device is prohibited.
The information and illustrations in this
manual were updated on the edition date
shown on the last page.
MECTRON
updating its products with possible changes
to the components of the apparatus.
In case you encounter discrepancies between
the descriptions found in this manual and the
equipment in your possession you can:
and
its
inserts,
dental practice or ambulatory.
The device cannot function in places where
there is an atmosphere saturated with
flammable gases (anaesthetic mixtures,
oxygen, etc.).
personnel. The device must be used
exclusively by specialized personnel such as
Surgeon. To use the device no special training
is requested. The use of the device does not
cause side effects if it is used correctly. An
improper use might cause tissues heating.
INTRODUCTION
is
engaged
• check for any available updates in
the
section MANUALS of MECTRON
website
;
1
• ask clarifications to Your Dealer;
• contact MECTRON After Sales Service.
• endodontics: all treatments for root
canals preparation, irrigation, filling,
condensation of the gutta-percha and
retrograde preparation;
• restoration and prosthesis: cavity
preparation, removal of denture,
condensation of the amalgam, finishing
of the cervical margin, inlay/onlay
preparation.
WARNING: The device must be used in a
WARNING: Risk of explosion.
WARNING: Qualified and specialized
in
continuously