S - ST SERIES WITH OVEN
Picture 8 - Multiflue cooker or thermal cooker with oven, predisposition of the correct flue outlet.
2.9
CORRECT CONJUNCTION TO THE CHIMNEY
If the conduct of the chimney starts from a lower
floor than the connection point of the device, it
may be necessary to close the conduct under the
connection pipe with fireproof materials. If you
have the chimney behind or up, you have to use
the connector with bayonet coupling. This must be
Picture 9 - Tolerance for flue outlet on the top and back. The tolerance depends on the orientation of the
connector.
The connection with the chimney must be always
well fixed and sealed, it must not have narrowing
and must not decrease the usable section of the
chimney (see picture 10). If near the cooker there
inserted and turned so that it can remain blocked.
This connector has a tolerance of about 1 cm to
make the installation easier. The tolerance is avail
able according to a single direction which depends
on the orientation of the connector (see picture 9).
Y
Y
+/
+/
10 mm
10 mm
is inflammable material or high temperatures sen
sible, the connection must be isolated and the
safety distances must be strictly observed.
89
X
X
+/
+/
10 mm
10 mm