Télécharger Imprimer la page

PREVOST MIRAGE XLII Serie Manuel De L'opérateur page 160

Publicité

INFORMATION TECHNIQUE
Code
Code
principal
secondaire
57
44
57
66
57
88
57
99
61
0
62
12
62
23
62
32
62
33
63
0
63
26
63
40
64
12
64
23
66
0
66
11
69
27
69
28
69
29
69
33
69
34
69
35
69
36
69
39
69
41
69
42
69
43
DESCRIPTION
Range verification C3PS test, 4
Range verification C3PS test, 6
Range verification C3PS test, N1
Range verification C3PS test, N2 or
N4
Retarder oil temperature, hot
Retarder oil temperature sensor, low No
Retarder oil temperature sensor,
high
Engine coolant sensor, failed low
Engine coolant sensor, failed high
Input function fault
Kickdown input, failed on
Service brake status input, failed on
Retarder modulation request sensor,
failed low
Retarder modulation request sensor,
failed high
Serial communications interface
fault
SCI engine coolant source fault
ECU, inoperative A-Hi switch
ECU, inoperative F-Hi switch
ECU, inoperative N and H-Hi switch
ECU, Computer Operating Properly
(COP) timeout
ECU, write timeout
ECU, checksum test
ECU, RAM self test
Communication chip addressing
error
ECU, I/O ASIC addressing test
SPI output failure
SPI input failure
Témoin
CHECK
TRANS
th
Yes
th
Yes
Yes
Yes
No
No
No
No
Yes
No
No
No
No
No
No
Yes
Yes
No
No
Yes
No
No
No
No
Yes
Yes
156
Description des messages
DNS, 5th or
SOL OFF (3rd), DNA
DSN, SOL OFF (5th), DNA
DNS, N3, DNA
DNS, N3, DNA
None
None
None
Use default value of 0°F
Use default value of 0°F
Depends on input function,
DNA
Kickdown operation
inhibited
No auto Neutral to Drive
shifts for refuse packer (I/O
package # 41).
Retarder operation inhibited
Retarder operation inhibited
Use default throttle values,
DNA
Use default value of 0°F
DNS, NNC, DNA
Lock up inhibited, DNA
Low and 1st inhibited,
retarder inhibited, DNA
RESET ECU, SHUTDOWN
ECU ON 2ND
OCCURRENCE (POWER
LOSS: HYDRAULIC
DEFAULTS), MAY CAUSE
"CATEYE" DISPLAY, DNA
DNS, SOL OFF
(Hydraulic default), DNA
Induce COP timeout
(4)
(reset ECU), DNA
INDUCE COP TIMEOUT
(4)
(reset ECU), DNA
Use default for J1939 data,
DNA
Induce COP timeout
(4)
(reset ECU), DNA
GPO 1-8 and reverse
warning inoperable
DNS, lock in range, DNA
(4)

Publicité