Code
Code
principal
secondaire
33
12
33
23
34
12
34
13
34
14
34
15
34
16
34
17
35
0
35
16
36
0
42
12
42
13
42
14
42
15
42
16
42
21
42
22
42
23
42
24
42
26
44
12
44
13
44
14
44
15
44
16
44
21
44
22
44
23
DESCRIPTION
Sump oil temperature sensor failed
low
Sump oil temperature sensor, failed
high
Factory calibration compatibility
number wrong
Factory calibration block checksum
Power off block checksum
Diagnostic queue block checksum
Real time block checksum
Customer modifiable constants
checksum
Power interruption (code set after
power restored)
Real time write interruption
Hardware/Software not compatible
Short to battery, A solenoid circuit
Short to battery, B solenoid circuit
Short to battery, C solenoid circuit
Short to battery, D solenoid circuit
Short to battery, E solenoid circuit
Short to battery, F solenoid circuit
Short to battery, G solenoid circuit
Short to battery, H solenoid circuit
Short to battery, J solenoid circuit
Short to battery, N solenoid circuit
Short to ground, A solenoid circuit
Short to ground, B solenoid circuit
Short to ground, C solenoid circuit
Short to ground, D solenoid circuit
Short to ground, E solenoid circuit
Short to ground, F solenoid circuit
Short to ground, G solenoid circuit
Short to ground, H solenoid circuit
Témoin
CHECK
TRANS
No
No
Yes
Yes
No
No
Yes
Yes
No
Yes
(2)
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
151
INFORMATION TECHNIQUE
Description des messages
Use default value of 200°F
(93°C)
Use default value of 200°F
(93°C)
DNS, SOL OFF (Hydraulic
default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
Use previous location or
factory calibration and reset
adaptive, DNA
Use previous location or
clear diagnostic queue, DNA
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
None (Hydraulic default
during interruption)
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF, DNA
DNS, SOL OFF, DNA
DNS, SOL OFF, DNA
DNS, SOL OFF, DNA
DNS, SOL OFF, DNA
Lock up inhibited, DNA
DNS, lock in a range
Differential lock inhibited
(3070 only), retarder
inhibited
Low and 1st inhibited
Low and 1st inhibited, allow
retarder
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
DNS, SOL OFF
(Hydraulic default), DNA
Lockup inhibited, DNA
DNS, SOL OFF
(Hydraulic default), DNA
Differential lock inhibited
(3070 only), retarder
operation inhibited