10.3.12.2 Display in the operating display with an active metering controller

Fig. 10.30 Display in the operating display with an active metering controller: Downward metering divergence
Fig. 10.31 Display in the operating display with an active metering controller: no metering divergence
Fig. 10.32 Display in the operating display with an active metering controller: Upward metering divergence
NOTE

10.3.13 Configuration / Metering monitoring

If the metering monitoring function is enabled, the pump strokes are compared to the
incoming pulses using a connected external metering monitor (e.g. oval gear meter). If a
configurable tolerance threshold is breached, an alarm is triggered.
The metering monitoring system can be connected at plug II (or plug V if a dongle box is
used) at Pin
chapter
10.3.13.5
connection see chapter
oval gear meter
If an oval gear meter is connected as a metering monitoring unit and should be
NOTE
correspondingly evaluated, then the configuration/oval gear meter function must be
enabled in addition to the configuration/metering monitoring function (see chapter 10.3.11).

10.3.13.1 Selecting

417101438_EMP_II_E60
▼ = Downward metering divergence
The pump is currently delivering less than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is increased automatically until the actual value
matches the target value.
- = No metering divergence
The pump delivers exactly the preset flow (here 100/min for example).
No correction is necessary.
▲ = Upward metering divergence
The pump is currently delivering more than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is reduced automatically until the actual value
matches the target value.
Fig. 10.33 Mounting note
2+4
(input pulse) or at Pin
"Metering monitoring / Input (only at E60 WITHOUT Dongle box)", electrical
7.2.3.5
"Installing the metering monitoring" and
(OGM
or
OGM
PLUS
Dongle-box mounted.
Oval gear meter OGM
3+4
(input metering lock) (assortment of inputs see
)").
- 111 -
mounted.
PLUS
8.2.1.1
Fig. 10.34 Configuration / Metering monitoring:
-
metering monitoring is inactive.
(Default setting)
✓ metering monitoring is active.
On activating metering monitoring, a
submenu appears with the following
menu items:
Menu item
see chapter
• Stop pump
10.3.13.2
• Strokes
10.3.13.3
• Deviation
10.3.13.4
• Input
10.3.13.5
"Installation
Selecting
Rev. 12-01.19