Technical Specifications "Overview Tables; General Data - Standard Pumps; Deviant General Data - Pumps In The "Higher Pressures (Hp)" Version; Materials - Ecolab Elados EMP II E60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14.3

Technical specifications "Overview tables"

Description
Supply voltage
max. current input
Motor Power
Fuse rating
Type of protection
Breaking capacity at circuit with 24 V
Breaking capacity at circuit with 230 V
*
The values at brackets refer to types 00072, 00112, 00240 with BLDC- Motor
(visible at the voltage indication 100- 240V at identification plate)
14.3.1

General data - Standard pumps

Description
Pump output
[l/h]* / **
max. metering backpressure [MPa
Number of strokes [1/min] at 50 Hz
Metering quantity/stroke [ml] 50 Hz/60 Hz
Metering accuracy [see chapter 14.4]
max. conveyable viscosity [mPas]
Permitted ambient temperature
Suction height [mWs] at 100 %
max. pre-pressure suction sided [MPa (bar)]
Noise level [DBA] at 1 m distance
(acc. to DIN EN 12639/ EN ISO 9614-2)
Recommended minimum diameter of
suction/pressure connector [ID mm]
Weight [kg]
*
All data relate to water at 20 °C
**
At mains power frequency of 60 Hz, the delivery capacity increases by 20%, while metering backpressure decreases by 20%.
***
Suction heights with clean, moistened valves at 100% metering stroke and max. stroke frequency
14.3.2

Deviant general data - Pumps in the "Higher Pressures (HP)" version

Description
Pump output
[l/h]*
max. metering backpressure [MPa (bar)]
Metering quantity/stroke [cm³]
*
all data relate to water at 20 °C
14.3.3

Materials

Pump head:
Diaphragm:
Seals:
Valves:
Ball valves:
Housing:
Colour:
Special versions available on request.
417101438_EMP_II_E60
V3014 V3025 00048 00043
115V 50/60 Hz
230V 50/60 Hz
115/230V 50/60 Hz
115 V
230 V
stroke signal output: connection according to VDE is not permitted
(bar)]**
0.1 (10) 0.8 (8) 0.4 (4)
stroke***
PVDF, optionally PP, stainless steel 1.4571
PTFE-EPDM composite diaphragm
FPM (Viton B), optionally EPDM, Kalrez
PVDF, optionally PP or stainless steel 1.4571
Ceramic, optionally stainless steel 1.4401, PTFE
thermoplastic polyester
Blue RAL 5007
Pump type
230 V / 50/60 Hz ± 10 % (special voltages on request)
0.12 A
0.20 A
0.06 A
0.21 A
10.4 / 11.5 W
18.7 W 19.8 W
315 mA
Empty report output: 24 V 3 A AC/DC
stroke signal output: 24 V 0.3 A DC
Empty report output: 230 V / 3 A AC/DC
V3014 V3025
00048
1.4
2.5
4.8
0.19
0.34
0.65
0.08 (0.8)
4
2
Pump type
V3014
1.2
0.16
- 137 -
00072
00112 00240
0,6 MPa 1 MPa
0.29 / 0.33 A (0.7
0.09 A
0.14 / 0.16 A (0.7
30 / 34.5 W (25
(1A)*
IP 65
Pump type
00043
00072
00112 00240
0,6 MPa 1 MPa
4.3
7.2
11.2
1 (10)
0.6 (6) 1 (10) 0.5 (5) 0.2 (2)
122
0.57
0.98
< ± 3%
200
5-40°C
2
0.05 (0.5)
54
6
2.4
3.1
V3025
00043
2
1.6 (16)
0.27
Rev. 12-01.19
A)*
A)*
W)*
24
1.5
3.28
0.02 (0.2)
3.3
4
0.55