14.1.2
Pump key 2
2 1
2 1
P V 9 9
9 9
Example of the complete pump key for a standard pump:
E60
V3025
PV 08
(Pump key 1)
417101438_EMP_II_E60
11. Suction-side connection
21
= Set for tube 4/6, 6/8, 6/12 *
12.Pressure-side connection
21
= Set for tube 4/6, 6/8, 6/12 *
13. Material connection
PV = PVDF
PP = PP
14. Electrical stroke adjustment
99
= no electrical stroke adjustment
15. Diaphragm breakage detection
99
= no diaphragm breakage detection
16. Housing version
01
= standard housing
0 1
Other specifications provided on request.
FP
KE
PV 99
01
03
-
21
21
PV 99
(Pump key 2)
- 134 -