9.7

Delivery condition

9.7.1

Basic setting of the mode of operation / display in the operating display

On delivery, the mode of operation internal is displayed in the version "display/ strokes".
Therefore, the following parameters are shown on the display when the main voltage is
switched on.
Fig. 9.8
Basic setting of the mode of operation / display in the operating display
NOTE
With each stroke of the pump, the indicator in the upper right of the display
9.7.2

Basic settings in the configuration

The following factory settings are defined in the configuration.
Fig. 9.9
Basic settings in the configuration
417101438_EMP_II_E60
Operating mode:
Metering frequency / - quantity: strokes / min (122 strokes / min at 50 Hz,
Operating state:
internal
146 H strokes / min at 60 Hz)
OFF (at V 4.1, „Standby" at V4.0)
(to start the pump press START / STOP key)
Configuration of
language:
unit:
code:
auto start:
metering lock:
low level contact:
alarm output:
pulse memory:
oval gear meter:
metering controler:
meter monitor:
microflow :
batch:
degas:
microflow
Only appears on the display in conjunction with the
MicroFlow
PLUS
accessory.
- 99 -
rotates 1 turn.
Standard
see Chapter
German
litre
not active (-)
not active (-)
not active (-)
open ()
off (⚫)
not active (-)
not active (-)
not active (-)
not active (-)
not active (-)
not active (-)
not active (-)
metering monitor, which is available as an
Rev. 12-01.19
10.3.3
10.3.4
10.3.5
10.3.6
10.3.7
10.3.8
10.3.9
10.3.10
10.3.11
10.3.12
10.3.13
10.3.14
10.3.15
10.3.16