Safety Switch-Off; Fault Overview/ Fault Reports - Sentiotec Wave.com4 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for assembly and use

3.14.0 SAFETY SWITCH-OFF

Your Wave.com4 sauna control unit is equipped with a safety cut-out via a safety temperature
limiter. This safety device is located in the sensor casing of the heater sensor which is located
above the sauna heater. Should the sauna heater fail to switch off after attaining the desired
temperature due to a defect of any kind, the safety temperature limiter automatically interrupts
the electrical circuit at approx. 139 ° C and switch es the sauna heater off.
Should a cut-out of this type occur, the safety temperature limiter must be
exchanged and an expert consulted under all circumstances.

3.15.0 FAULT OVERVIEW/ FAULT REPORTS

Your Wave.com4 sauna control unit is equipped with sophisticated diagnostic software.
The self-test is performed during control unit start-up. The system statuses are verified both during
this test and while using the sauna control unit. As soon as the diagnostic software recognises a
fault in the system, the Wave.com4 sauna control unit switches off automatically.
In this case, all operating symbols of the operating unit flash and a fault number appears. The
following table gives information on possible faults and their cause if necessary.
Inform service personnel of the fault notification. This can help to locate the error and
find a solution more quickly if necessary.
In the event of a fault, a reboot may be useful and may rectify the fault. To do this,
disconnect the control unit from the mains at all poles (deactivate main switch).