(Seite 42]
Special functions
Temperature zero calibration
If you replace the temperature sensor you may find that it is necessary to re-calibrate the temperature.
This is the procedure:
The whole turbine must be at room temperature (approx. 21°C) !
Press and hold the "Select Menu" button on the GSU, then switch on the Jet-tronic (via the receiver switch).
* Note:
You can also use the small button on the LED board instead of the "Select Menu" button on the
GSU.
Initially the three LEDs will flash in the following sequence:
LED
Standby
Pump running
OK
(while the LEDs are flashing in this sequence hold the button pressed in - don't release it !!!)
Release the button only when the three LEDs start flashing in the following sequence:
Airspeed
Sensor
40cm
Airspeed
Sensor
Flashing sequence
Schritt 4
Step 4
Schritt 5
Step 5
40