[Seite 11]
Connection diagram B, JetCat P80 / P120
The advantage of this arrangement is that any leaks in the filler system have no effect on the fuel supply to
the turbine. Disadvantage: slightly more complex installation.
In general terms we recommend keeping the fuel line as short as possible on the inlet side of the pump (risk
of serious build-up of low pressure -> bubble formation due to cavitation). On the pressure (outlet) side of the
pump the length of the fuel line is not so critical.
* Important:
Complete the connections at the fuel shut-off valve as shown in the drawing, i.e. the fuel line from the fuel
filter to the valve must face in the direction of the black heat-shrink sleeve (on the valve)!
Tip:
You will find that the fuel lines can be pushed onto the nipples of the fuel valve relatively easily if you heat
the end of the tubing slightly beforehand (with a flame or a heat-gun).
to turbine (zur Turbine)
Fuelpump
(Pumpe)
Shut-off
valve
( Ventil )
IN
OUT
Filter
out
in
Entlüftung
tank fill connector
(Befüllungsanschluß)
10
main tank ( Haupttank)
Tankpendel
clunk