Resetting The Electronics To The Default Values - GRAUPNER JetCat P60 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LED
Standby
Pump running
OK
The GSU screen then simultaneously displays the message:
Release key to:
Calibrate Temp
[Seite 43]

Resetting the electronics to the default values

The method for resetting the ECU to the default settings is as follows:
Press and hold the "Select Menu" button on the GSU, then switch on the Jet-tronic (via the receiver switch).
* Note:
You can also use the small button on the LED board instead of the "Select Menu" button on the
GSU.
Initially the three LEDs will flash in the following sequence:
LED
Standby
Pump running
OK
(while the LEDs are flashing in this sequence hold the button pressed in - don't release it !!!)
After about 15 seconds the three LEDs will then start flashing in the following sequence:
LED
Standby
Pump running
OK
(while the LEDs are flashing in this sequence hold the button pressed in - don't release it !!!)
Release the button after about 40 seconds, when the three LEDs start flashing in the following sequence:
LED
Standby
Pump running
OK
The GSU screen then displays the following message:
Release key to:
Reset System
* Note:
After carrying out a reset you will need to repeat the following procedures:
The radio control system must be re-"learned" (-> page 18).
The initial fuel pump voltage must be re-adjusted (-> page 12).
The temperature zero calibration process must be repeated (-> page 42).
Flashing sequence
Flashing sequence
Flashing sequence
Flashing sequence
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jetcat p80Jetcat p120Jetcat p160679867996800 ... Afficher tout

Table des Matières