The RUN menu

As soon as the Jet-Tronic is switched on, the screen displays the Run menu. The bottom line of the screen
shows the current rotational speed of the turbine under "RPM:".. The top line of the screen can display
various other items of information, which are selected using the +/- buttons:
Name
U-Pump
Temp.
OffCnd
State
AirSpeed
SetSpeed
SetRpm

The INFO menu

The following information can be displayed in the Info menu:
Name
Rest Fuel
Fuel flow ml/min
BattCnd
Ubattery
Last Run-Time
Last fuel count
Last-Off RPM
Last-Off TEMP
Last-Off Cond
Last-MaxAirSpd
Explanation
Current pump voltage in Volts.
Current turbine exhaust gas temperature in °C or °F.
The temperature display unit (°C or °F) can be set in the LIMITS menu.
Last reason for shut down (see table).
Current state of turbine (see table 1, page 24).
Current airspeed in km/hr. This display option is normally only used to check the
function of the airspeed sensor (= pitot tube).
Note: this display option is only available if an airspeed sensor is connected.
Nominal airspeed in km/hr. This display option is used to check the nominal airspeed
which is pre-set by the throttle stick in "Speed control" mode.
Note: this display option is only available if an airspeed sensor is connected.
Nominal rotational speed of the turbine.
Explanation
Remaining fuel volume in fueltank
Current fuel consumption in ml/min.
The top line displays the state of the turbine battery:
a) --OK--
b) ! WEAK !
a) If the battery voltage is higher than 1.1 V/cell.
b) If the battery voltage falls below 1.1 V/cell the message "! WEAK !" (= almost
discharged) appears, and the "Standby" and "OK" LEDs flash simultaneously at 0.5
sec. intervals. The turbine cannot be started until the battery is recharged. If the
turbine is already running and the battery warning function has been switched on, the
warning function is triggered at this point.
c) If the battery voltage falls below 1.0 V/cell the screen shows "--EMPTY--" and the
turbine is shut down. The turbine cannot be started again until the battery is
recharged.
The bottom line of the screen displays the voltage of the turbine battery
Last turbine run time
Quantity of fuel consumed during last turbine run
Rotational speed last time the turbine was shut down
Temperature at which the turbine was shut down
Last stored reason for shut down
Maximum airspeed measured during the last flight (only if an AirSpeed Sensor is
connected!)
c) --EMPTY--