Instructions For Installing The External Version Of The Interface - Fronius Profibus Instructions De Service

Masquer les pouces Voir aussi pour Profibus:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Application
example - TSt
range
Application example TSt range
(1) Cooling unit
(2) Power source
(3) Profibus
(4) Interconnecting hosepack
(5) Wire-feed unit
(6) Welding torch
(7) Robot control
(8) Welding wire drum
(9) Robot
(10) Profibus data cable
Instructions for
installing the
external version
of the interface
(3)
(2)
(1)
(10)
NOTE! The following guidelines must be followed when installing the external
version of the interface:
-
The cables must be routed separately from mains leads
-
The field bus coupler must be installed separately from the mains leads or
components
-
The field bus coupler may only be installed somewhere that provides protec-
tion from dirt and water
-
Make sure that the 24 V supply voltage is safely isolated from higher-voltage
circuits.
(5)
(4)
5
(6)
(7)
(8)
(9)