Connecting and
Important! Before starting up, check that the shield is connected to the robot earth.
configuring the
field bus coupler
In systems with more than two power sources, wire the power sources in parallel.
(continued)
Profibus pin assignment
For the TS/TPS, MW/TT series:
8.
For the TSt series:
8.
9.
Slave address
Set slave address using the two rotary selector switches.
Default setting = 11
configuration
All addresses are permitted, each address may only appear once on the network.
1.
2.
3.
Important! Ensure that the switches engage properly
4.
NOTE! In order to avoid reflections and any transmission problems, fit resistors
to both ends of the field bus cable.
Power source 1
RxD/TxD-P (3)
DGND (5)
RxD/TxD-N (8)
DIN rail
Connect the LocalNet plug on the interconnecting hosepack to the LocalNet connec-
tion on the interface
Connect the LocalNet plug on the interconnecting hosepack to the LocalNet OUT
connection
Connect the LocalNet connection on the power source to the LocalNet IN connection
on the interface using a LocalNet cable
Ensure that all devices and components have been switched off and disconnected
from the mains
Ensure that the interface has been disconnected from the mains
Move switch to desired position using a screwdriver.
-
Values on the upper switch represent units
-
Values on the lower switch represent tens
0
x 1
0
x 10
Using the original screws, fit the interface lid back into its original position
Power source 2
Shield
DIN rail
Example
Setting address 34:
-
Upper rotary selector switch: 4
-
Lower rotary selector switch: 3
8
RxD/TxD-P (3)
DGND (5)
RxD/TxD-N (8)