Connections
Changing the IP address on the unit to match
the IP address of the remote camera or
switcher
[Remote camera settings]
The unit sets the IP addresses for the remote
cameras that have been detected by associating
them with camera numbers whose connection
setting is set to "NoAsign".
Connection settings:
On the [SYSTEM] menu, select [CAMERA CTL],
and then display items [CAM1] to [CAM100].
Setting or changing IP addresses:
On the [SYSTEM] menu, select [CAM IP ADR],
and then display items [CAM1] to [CAM100].
Example:
 Three remote cameras are in operation.
 An additional remote camera with an IP
address of "192.168.000.020" is newly
introduced (and becomes remote camera E).
 Remote camera E is detected.
 In [CAMERA CTL], the [CAM4] item is set to
"NoAsign".
In the above example, on the [SYSTEM] menu, in
[CAM IP ADR], the IP address of the [CAM4] item
is set to "192.168.000.020".
 Subnet mask, default gateway, and port number
settings are the same as those for the unit.
[Switcher settings]
The IP address for the switcher will be set in the
[IP:SW] item from [SW IP ADR] on the [SYSTEM]
menu.
Note
If different subnet mask settings are used for
unit and remote camera, no operations using the
network will be possible.
All manuals and user guides at all-guides.com
1
2
 Memo 
  If the number of new devices detected exceeds
  The number displayed for "Number of new devices
31 (E)
Connect the additional remote cameras
and the switcher to be introduced and
the unit to the network within the same
subnet.
On the [SYSTEM] menu, select [AUTO
SET IP], and display [AUTO SETUP]. Then
select "KEEP IP ADR", and press the F2
dial.
1.AUTO SETUP
KEEP IP ADR
Both the number of devices (all remote cameras
and the switcher) currently being managed by the
unit and the number of new devices detected are
displayed on the LCD panel.
C:001/004 S:0/1
YES
C:001/004
Number of devices currently
managed by the unit + Number of
new devices detected
Number of new devices detected
C: Remote camera, S: Switcher
the number of devices that can be registered
(100 remote cameras and 1 switcher), [C/S OVER!]
will be displayed at the bottom of the LCD panel.
Automatic IP address setting can be performed
even in this state, but IP addresses will be set only
for the number of devices that can be registered.
C:020/100 S:1/1
C/S OVER!
detected" may be lower than the actual number
of devices to be set, due to a cause such as the
remote cameras or switches not being powered on.
In this case, eliminate the cause of the problem,
select "RETRY", and then press the F2 dial to retry
the operation.
The number of units to be added can be updated.
C:020/020 S:1/1
YES
RETRY