Commands and Accessories
If not installed, safety devices with NC contacts must be jumpered at the COM terminals, or disabled by modifying
the parameters
,
N.C. (Normally Closed).
CONTACT
13 (COR)
14
13 (COR)
14 Error alert contact only, for:
16(+LAM)
15(COM)
17(+ES)
15(COM)
18(+24V)
15(COM) Power feed for external devices; see table "PRODUCT TECHNICAL FEATURES" on page 52
20(SC)
19(COM) Connection for gate open indicator lamp. 24
20(SC)
19(COM) Photocell test connection
22(FT2)
21(COM)
23(FT1)
21(COM)
24(COS2)
26(COM)
25(COS1)
26(COM)
27(ST)
26(COM)
58
,
,
,
and
.
DESCRIPTION
Output (potential free contact) for connecting courtesy light. 230
• control unit in alarm / battery supply error (low battery);
The COR output operating mode is managed by parameter
The voltage level of the battery can be set via parameter
The function of the indicator lamp is determined by parameter
Set the parameter
to enable the test function.
contact changes state correctly.
Power feeds for all external devices may be connected to reduce battery consumption (if batteries are
used). Set
or
.
WARNING! If contact 20 (SC) is used for the photocell test function or battery saving function, a gate
open indicator lamp cannot be connected.
The photocells FT2
. Photocell FT2 disabled when gate is opening.
. Photocell FT2 disabled when gate is closing.
. The gate opens when an open command is received if photocell FT2 is obstructed.
. NC (normally closed) incoming contact.
If the photocells are not installed, jumper the terminals 21(COM) - 22(FT2) or set the parameters
and
.
WARNING! Use R90/F4ES, G90/F4ES or T90/F4S series photocells.
The photocells FT1
. Photocell triggers only during gate closure. Photocell is ignored during gate opening.
. Movement is reversed if the photocell is triggered during gate closure.
. The gate opens when an open command is received if photocell FT1 is obstructed.
. NC (normally closed) incoming contact.
If the photocells are not installed, jumper the terminals 23(FT1) - 21(COM) or set the parameters
and
.
WARNING! Use R90/F4ES, G90/F4ES or T90/F4S series photocells.
. The sensing edge COS2 (NC contact) is disabled.
If the sensing edge is not installed, jumper the terminals 24(COS2) - 26(COM) or set the parameter
.
. If the sensing edge COS1 (NC contact) is enabled, the gate always reverses.
If the sensing edge is not installed, jumper the terminals 25(COS1) - 26(COM) or set the parameter
.
The current manoeuvre is arrested if the safety contact opens.
N.B.: the controller is supplied with this contact already jumpered by ROGER TECHNOLOGY.
. (normally closed) incoming contact.
(24
duty cycle
.
max. 15 W
; see table "PRODUCT TECHNICAL FEATURES" on page 52
FT2
FT1
COS2.
COS1
/
.
.
.
.
, while