10.2
Command and safety device status display mode
COMMAND STATUS
AP
PED
PP
CH
ORO
POWER
10.3
TEST mode
To activate the mode, press the TEST button with the automatic gate system at rest. If the gate is moving, pressing
TEST stops the gate. Pressing the button again enables TEST mode.
device is activated.
The command signal status is shown on the left hand side of the display for 5 seconds, ONLY when the respective
command signal is active (AP, CH, PP, PE, OR). For example, if the gate open command is activated, the letters AP
appear on the display.
The status of the safety devices/inputs is shown on the right hand side of the display. The number of the terminal
Example: STOP contact in alarm state.
NOTA: If one or more contacts are open, the gate will not open or close.
the next device is displayed. Any further alarm states are also displayed with the same logic.
Press the TEST button again to exit test mode.
After 10 seconds with no user input, the display returns to command and safety device state display mode.
10.4
Standby mode
This mode is activated after 30 minutes with no user input. The POWER LED
Press UP
, DOWN
, + , - to reactivate the control unit.
FT1
FT2
COS1
COS2
STOP
No safety device in alarm state, and no limit switch activated
STOP.
Sensing edge COS1.
Sensing edge COS2.
Photocell FT1.
Photocell FT2.
Parameter
on the display, then repeat the acquisition procedure (see chap. 9).
COMMAND STATUS:
The command status indicators on the display
(segments AP = open, PP = step mode, CH = close,
PED = partial opening, ORO
off. They illuminate when a command is received
(e.g.: when a step mode command is received, the
segment PP illuminates).
SAFETY DEVICE STATUS:
The safety device status indicators on the display
(segments FT1/FT2=photocells, COS1/COS2 =
sensing edges, STOP) are normally on. If an indicator
is off, the relative device is in alarm state or is not
connected.
PROG
POWER
are normally
appears
61