6.2
Electrical connections
buffer batteries before performing any cleaning or maintenance operations.
practices and in compliance with applicable legislation.
(brown) and N (blue), located inside the control panel box.
Strip the insulation from the ends of the power cable wires which will be connected to the
Measure the voltage on the primary mains power connection with a tester.
TRANSFORMER
For the Brushless automation system to function correctly, the mains
power voltage must be:
220÷230
A
V
N L
V
A
+
-COM
in the external section to the electrical panel must be on an independent path and
The cables must be double insulated, strip them near the relevant connection terminals and
N L
SEC2
SEC1
X-Y-Z
Y
M
X
Z
Z-Y-X
Y
M
Z
X
BATTERY
- +
DESCRIPTION
60Hz).
Fuse 5x20 T2A.
Secondary transformer input for 26
cal control and peripheral devices (SEC2).
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connection to ROGER brushless MOTOR 1.
Warning! If the motor rotates in the wrong direction, simply swap any two of the three
motor connectors.
Connection to ROGER brushless MOTOR 2.
Warning! If the motor rotates in the wrong direction, simply swap any two of the three
motor connectors.
Connection to B71/BCHP (see
See instructions for B71/BCHP for further information.
EDGE1/115/BOX: 115
motor power (SEC1) and for 19
power to logi
57