01= the gate decelerates near stops and the limit switch (if installed).
...
05= the gate decelerates long before stops and the limit switch (if installed).
Adjusting LEAF 1 position control when completely opens or closes
The value selected must ensure that LEAF 1 is opened/closed correctly when it reaches the respective (open or closed)
mechanical stop. The position of LEAF 1 is calculated by the system from the number of motor revolutions and the
motor reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate open stop.
N.B.: with BR21 automation systems, with the gate leaf in the completely closed position, adjust the inner mechanical
stop so that the lever of the gear motor can move by a few millimetres.
Adjusting LEAF 2 position control when completely opens or closes
The value selected must ensure that LEAF 2 is opened/closed correctly when it reaches the respective (open or closed)
mechanical stop. The position of LEAF 2 is calculated by the system from the number of motor revolutions and the
motor reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate closed stop.
N.B.: with BR21 automation systems, with the gate leaf in the completely closed position, adjust the inner mechanical
stop so that the lever of the gear motor can move by a few millimetres.
Motor revolutions (
= minimum /
= maximum).
Partial opening adjustment (%)
N.B.: with double leaf swing gate installations, this parameter is set by default as the completely open position of
LEAF 1.
of total gate travel.
Type of signaling provided by COR output
STANDARD operation managed by parameter
Contact closed if the control unit is powered by the mains or charged battery.
Open contact due to a fault: control unit powered by low battery (voltage level set by par.
) or with error alert
(the control unit no longer accept commands).
Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs .
Closed contact if the gate is not completely open.
Open contact if the gate is completely open.
Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.
Adjusting stop advance of LEAF 1 when opening
Adjusting stop advance of LEAF 2 when opening
The leaf stops against the opening stop.
A leaf stop advance of 1 to 25 motor turns before the completely open position may be set.
Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate closes
automatically. The timer count restarts if a photocell is triggered.
IMPORTANT: persistent activation of the opening command prevents automatic reclosure; the automatic reclosure time
count is resumed when the opening command is released.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Enabling of management for opening with automatic reclosure exclusion
If enabled, the exclusion of automatic reclosure only applies for the command selected via the parameter. For example:
if you set
, automatic reclosure is excluded following an AP command, but it is activated following a PP or PED
command.
NB:
Disabled.
An AP (opening) command activates the opening manoeuvre. With the gate fully open, automatic reclosure is excluded.
An AP (open) or CH (close) command activates the closure manoeuvre.