message "
" and bypassing the safety devices installed (photocells, sensing edges and STOP button) with the
exception of the obstacle detection system. MOTOR 1 is controllable when the messages:
appear on the display. MOTOR 2 is controllable when the messages
Example:
p1
or
p2
• THE MOTOR in question is activated on opening by pressing the
• For safety, the open and close functions are only available in continuous control (operator present) mode: press the
button, release within 1 second and then press and hold. The motor stops as soon as the button is released.
WARNING: during the check, the motor revolution count (position) is updated but the gate leaf alignment control
function may cause problems. Before exiting INFO, make sure that the gate leaves are correctly aligned.
• Press and hold the TEST button for a few seconds to exit INFO mode.
16.1
B74/BCONNECT mode
By inserting B74/BCONNECT in the EXP connector, all the functions are managed through internet browser and devices
such as smartphones, tablets, PCs, exploiting WiFi communication, tablet, PC, all the functionalities of the central unit
are managed, using the WiFi communication.
For further information consult the installation manual of the connection module B74/
BCONNECT connection module.
Remote assistance" mode
Allows access and therefore the management of all the data of the control unit only in cloud mode and therefore with
remote management.
When remote assistance is enabled, the message ASCC (assistance connect controlled) appears on the display.
By pressing the TEST button this message disappears for 10 seconds, and it is possible to access the parameters
and other functions of the display.
reappears.
"Emergency operation" mode
This mode is used to exclude motor and safety alarms (e.g. photocells and sensitive edges), allowing the automation
to open and close at low speed and with the operator present, with movement of the leaves only in the presence of a
persistent command (when the command is released, the leaves stop).
Two types of "emergency" mode are possible: residential or condominium.
1) residential
L-ES display indication): the PP command (from the terminal board or radio control) is initially
managed as an opening command; only when complete opening has been reached will activation of the command
send it to closing. Only when complete closure has been achieved will the command be able to open again.
2) condominium
but once it has been fully opened the leaves no longer close.
By pressing the TEST button this message disappears for 10 seconds, and it is possible to access the parameters
and other functions of the display.
ASCC
"Remote assistance" mode enabled
L-ES
"Residential emergency operation" mode enabled
L-EM
"Condominium emergency operation" mode enabled
17
Mechanical release
1-PRESS
2-RELEASE
OPEN
CLOSE
OPEN
or
,
,
and
3-RE-PRESS
CLOSE
OPEN
or
within 1 s
,
,
and
appear on the display.
CLOSE
or