Télécharger Imprimer la page

Roger Technology EDGE1 Instructions Et Consignes Pour L'installateur page 69

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 122
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents the
gate from closing when not required.
If automatic closing is disabled (
Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
Condominium function for partial open command (PED)
Enabled. Partial commands are ignored during gate opening.
Enabling operator present function
Disabled.
Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops when
the button is released.
Gate open indicator / photocell test function and "battery saving"
The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
if the output SC
NB: the type of photocell test can be selected by means of parameters
Set to
if the output SC
When the gate is completely open or closed, the control unit deactivates any accessories connected to terminal SC to
reduce battery consumption.
Set to
if the output SC
of photocell test can be selected by means of parameters
PARAME-
SMARTY5 o 7 SMARTY7R SMARTY5R5 SMARTY4/HS
BE20/200/
TER
HS
Setting deceleration MOTOR 1 during OPENING
Setting deceleration MOTOR 2 during OPENING
= the gate decelerates near stops and the limit switch (if installed) ...
(*)
= the gate decelerates long before stops and the limit switch (if installed).
(*)
for SMARTY Series automations
Setting deceleration MOTOR 1 during CLOSING
Setting deceleration MOTOR 2 during CLOSING
= the gate decelerates near stops and the limit switch (if installed) ...
(*)
= the gate decelerates long before stops and the limit switch (if installed).
for SMARTY Series automations
(*)
Setting deceleration MOTOR 1 during opening and closing
Setting deceleration MOTOR 2 during opening and closing
), the condominium function automatically attempts a closing manoeuvre
Parameters visible ONLY if:
ONLY IF
= SMARTY/EMA ENABLED
IF parameters
and
and
.
BH23/252/
HS
and
are visible, then:
.
NB: the type
BR21/351/
BE20/400 BR20/400/R
HS
.
69

Publicité

loading