Electrical
Voltage
Rated frequency
Rated current
Power consumption
Power consumption* in
Standby mode
* No option installed
Interface
The parallel interface connector pin assignments and a description of the interface
signals are shown in the table below.
Signal
Return
Pin
Pin
1
19
2
20
3
21
4
22
5
23
6
24
7
25
8
26
9
27
10
28
120 V model
90 V to 132 V
50 Hz to 60 Hz 3 Hz
5.5 A 10%
Less than 500 W
Less than 15 W
Signal
Direction
STROBE
IN
DATA 1
IN
DATA 2
IN
DATA 3
IN
DATA 4
IN
DATA 5
IN
DATA 6
IN
DATA 7
IN
DATA 8
IN
ACKNLG
OUT
220 V model
198 V to 264 V
50 Hz to 60 Hz 3 Hz
3 A 10%
Less than 600 W
Less than 15 W
Description
STROBE pulse to read data. Pulse
width must be at least 0.5 µ s at the
receiving terminal.
These signals represent parallel
data bits 1 to 8, respectively. Each
signal is at HIGH level when data
is logical 1 and LOW when it is
logical 0.
About a 1- µ s pulse width. LOW
indicates data has been received
and the printer is ready to accept
more data.
Technical Specifications
A-5