STEP 6
STEP 6
6.1 CONNECTING THE DEVICES INCLUDED IN THE
SYSTEM
After installing all the system devices – each in the position specified in
"STEP 4" and "STEP 5"– connect each device to the control unit in the
following way.
WARNING! – An incorrect connection can cause faults or danger-
ous situations; therefore ensure that the specified connections
are strictly observed.
01. Open the cover by loosening the screw (Fig. "32") and pressing
the button (Fig. "33").
32
33
02. Remove the disc [S] using a screwdriver (
34
S
03. Pass the cables through the holes [S] (
35
S
04. To make the connections, refer to Fig. "36" and the description of
05. Once you have connected all the cables, secure them using cable
06. To close the cover, push it back into place, making sure you hear
6.2 When connecting the power supply
Fig. "34""
).
• Never cut or remove the power cord supplied.
• If it is not already available, create a power outlet for MD432KM.
This operation must be carried out by qualified and expert
personnel in strict conformity to the current legislation, regulations
and standards.
The MD432KM must be connected to the power supply by a
qualified electrician.
To test the MD432KM, plug it into a power outlet using an extension if
necessary (Fig. "37").
Fig. "35""
).
the connections shown in Table 3 (par. 5.5): if you use the warning
light antenna, remove the piece of wire (connected by default to
terminal 14) and connect the type RG58 shielded cable.
clips.
a "click". Reinsert and tighten the screw to finish.
36
WARNING!
37
15
15