Télécharger Imprimer la page

moovo MD432KM Instructions Et Avertissements Pour L'installation Et L'utilisation page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9
10
A
A
Technical specifications of electrical cables (note 1)
Devices
A
Safety photocells
B
Control button
Safety button –
C
sensitive edges
– etc.
Note 1 – The cables required for setting the system up (not included in the set) may vary in relation to the quantity and type of
devices included in the system.
Note 2 – The connections to terminals 1-2 (Stop), 3-4 (Step-by-step) and 3-5 (Photo) can be made using a single cable with
several internal wires.
WARNING! – The cables used must be suited to the installation environment; for example a cable type H03VV-F for
indoor environments is recommended.
10
10
Terminals
Function
3 - 5
PHOTO input
3 - 4
STEP-BY-STEP input
1 - 2
STOP input
B
A
A
C
Type of cable
TX 2 x 0.25 mm
cables
2
RX 3 x 0.25 mm
cables
2
2 x 0.25 mm
cables
2
2 x 0.25 mm
cables
2
Maximum admissible length
20 m (note 2)
20 m (note 2)
20 m (note 2)
20 m (note 2)

Publicité

loading