LIM 0 input X
p20228
LIM 1 input X
p20236
1
2
Free function blocks - Control function blocks
LIM 0 ... 1
LIM (limiter)
LIM 0 upper lim LU
LU
-340.28235E36 ... 340.28235E36
p20229 (0.0000)
X
(0)
LIM 0 lower lim LL
LL
-340.28235E36 ... 340.28235E36
p20230 (0.0000)
LIM 1 upper lim LU
LU
-340.28235E36 ... 340.28235E36
p20237 (0.0000)
X
(0)
LIM 1 lower lim LL
LL
-340.28235E36 ... 340.28235E36
p20238 (0.0000)
3
4
LIM 0
LIM 0 RTG
5 ... 9999
p20234 (9999)
LIM 0 QU
QU
r20232
LIM 0 output Y
Y
r20231
LIM 0 QL
QL
r20233
LIM 0 RunSeq
0 ... 32000
p20235 (640)
LIM 1
LIM 1 RTG
5 ... 9999
p20242 (9999)
LIM 1 QU
QU
r20240
LIM 1 output Y
Y
r20239
LIM 1 QL
QL
r20241
LIM 1 RunSeq
0 ... 32000
p20243 (650)