Parameters
Symbol
Meaning
Parameter name [Unit]
Monitoring parameter with
rxxxx[y..z]
unit [Unit] and index range
[y..z] or data set [C/D]
Parameter name
Setting parameter
from ... to [Unit]
with min/max value
pxxxx[C/D] (Def)
and unit [Unit] data
set [C/D] and factory
setting (Def) *)
Data sets
Symbol
Meaning
pxxxx[C]
Parameter belongs to the
Command Data Set (CDS).
pxxxx[D]
Parameter belongs to the
Drive Data Set (DDS).
pxxxx[E]
Parameter belongs to the
Encoder Data Set (EDS).
pxxxx[M]
Parameter belongs to the
Motor Data Set (MDS).
pxxxx[P]
Parameter belongs to the
Power unit Data Set (PDS).
*)
For some parameters the value for the factory setting is calculated during commissioning for they are dependent on Power Module and motor (see Section 2.1.1 "Calculated").
1
2
Explanations on the function diagrams
Explanation of the symbols (part 1)
Connectors
Symbol
Meaning
Connector input CI
Parameter name
with index range [y..z]
pxxxx[y..z]
(Def)
or data set [C/D]
and factory setting
(Def) *)
Parameter name [Unit]
rxxxx[y..z]
Connector output CO with
unit [Unit] and with index
range [y..z]
CI: Connector Input
CO: Connector Output
CO/BO: Connector/Binector Output
Information on parameters, binectors, connectors
Symbol
Meaning
Parameter name
Parameter name (up to 18 characters)
[Unit]
[dimension unit]
rxxxx[y] or
"r" = monitoring parameter. These parameters are read-only
rxxxx[y..z] or
"xxxx" stands for the parameter number
rxxxx[y].ww or
"[y]" specifies the applicable index, "[y..z]" specifies the index range
rxxxx.ww
".ww" specifies the bit number (e.g. 0..15).
pxxxx[y] or
"p" = setting parameter. These parameters can be changed.
pxxxx[..z] or
"xxxx" stands for the parameter number,
pxxxx[y].ww or
"[y]" specifies the applicable index, "[y..z]" specifies the index range ".ww"
pxxxx.ww
specifies the bit number (e.g. 0..15).
from ... to
Value range.
(xxxx[y].ww)
Parameter number (xxxx) with Index number [y] and bit number .ww.
(Def)
Factory setting.
(Def.w)
Factory setting with bit number as prefix.
[aaaa.b]
Diagram references for setting parameters that occur a multiple number of times.
[Function diagram number, signal path]
3
4
Binectors
Symbol
Meaning
Binector input BI with
Parameter name
with index range [y..z] or
pxxxx[y..z]
data set [C/D] and
(Def.y)
factory setting.bit
number (Def)
Parameter name
Binector output BO
rxxxx
Parameter name
BI: Binector Input
BO: Binector Output
5
6
fp_1020_97_61.vsd
13.03.2018
Connectors/binectors
Symbol
Meaning
Parameter name
rxxxx
Connector/binector output
CO/BO
rxxxx
Pre-assigned connectors and binectors
Symbol
Meaning
Setting parameter with
min/max value and unit
from ... to [Unit]
[Unit] data set [D] and
pxxxx[D] (Def)
factory setting (Def)
Cross references between diagrams
Symbol
Meaning
Signal
The function diagrams are sub-divided into
path
signal paths 1 ... 8 in order to facilitate
orientation.
Text
Text = Unique signal designation
[aaaa.b]
aaaa = Signal to target diagram aaa
b
= Signal to signal path b
Text
Text = Unique signal designation
[cccc.d]
cccc = Signal from source diagram cccc
d
= Signal from signal path d
To "function diagram name" [aaaa.b] = binectors.
Cross references for control bits
Symbol
Meaning
pxxxx= Original parameter of signal
pxxxx
aaaa = Signal from source diagram aaaa
[aaaa.b]
b
= Signal from signal path b
7
Function diagram
G120 CU230P-2
V4.7_10
8
- 1020 -